Located in Prince George, British Columbia, the six-storey, eight-level Wood Innovation Design Centre was the tallest multi-use wood building in North America at 29.5 meters (97 feet) tall. It’s structural frame is built from cross laminated timber (CLT) panels and other laminated wood members to demonstrate that tall wood buildings can be structurally sound, cost-effective and beautiful. The Provincial Government’s goal was to push the limits of innovation beyond what was normally allowed by BC Building Codes.
For this project, the BC Provincial Government adopted a Site-Specific Regulation (SSR) specifically authorizing this one building to be built as a demonstration project, and directing the use of Alternative Solutions to meet structural building codes. Keys to success were a clear vision for the project, and the use of “alternative solutions” including modelling and analysis to ensure structural building code compliance, while entrusting its execution to an experienced design team, a rigorous peer review process and a trusted general contractor. The project team used several innovations to satisfy structural loads and procedures requirements including: the use of vertical cross-laminated timber (CLT) elements in the building’s structural core (mechanical, elevator and stair shafts) for lateral stability; the use of double layer CLT panels for the structural floor section; the use of load-bearing end-grain-to-end-grain glulam columns running continuously from foundation to roof; and finally high strength proprietary connectors, to achieve structural performance.
Code Requirement | Compliance Path |
---|---|
Building Structural Loads and Procedures, Sec 4.1-4.3 | Alternative Solutions compliance path authorized by Site-Specific Regulation SSR M.203 that specified building height and occupancy specifically for this building; substitute language and authority for alternative solutions adopted by signature of Minister. |
Building Structural Design requirements, Sec. 4.1.8.9(1) and 4.3.1.4(1) | Design team developed an alternative solution conforming to new section 4.1.8.9(6) in SSR M.203 that specified an R-factor of 2.0 and an Overstrength factor of 1.5 for construction with cross laminated timber panels with ductile connections. Their solution was approved based on Engineer’s Letter of Assurance and verification of structural performance model |